How Electrical Conductivity and Temperature-rise Limitations Impact LV Switchboards

Credit to Author: Pascal Lepretre| Date: Mon, 27 Aug 2018 13:00:27 +0000

The first post in this series explained why following IEC 61439 ensures quality switchboards, panels and assemblies. In short, adhering to the standard means that everything in an assembly works… Read more »

The post How Electrical Conductivity and Temperature-rise Limitations Impact LV Switchboards appeared first on Schneider Electric Blog.

Read more

With IEC 61439, Assure Thermal Stability and Reliability in Low Voltage Electric Switchboards

Credit to Author: Pascal Lepretre| Date: Tue, 10 Jul 2018 12:00:52 +0000

As detailed in the first post in this series, the main reason for following IEC 61439 is that doing so ensures quality of low voltage electric switchboards, panels and assemblies…. Read more »

The post With IEC 61439, Assure Thermal Stability and Reliability in Low Voltage Electric Switchboards appeared first on Schneider Electric Blog.

Read more

Ensure Short Circuit Withstand Strength in Low Voltage Electric Switchboards

Credit to Author: Pascal Lepretre| Date: Thu, 28 Jun 2018 12:30:57 +0000

The initial post in this series covered the reasons behind IEC 61439, which when followed ensures the quality of low voltage electric switchboards. Other posts how shown how the standard… Read more »

The post Ensure Short Circuit Withstand Strength in Low Voltage Electric Switchboards appeared first on Schneider Electric Blog.

Read more

Clearances and Creepage Distances in LV Electrical Switchboards

Credit to Author: Pascal Lepretre| Date: Wed, 06 Jun 2018 13:00:04 +0000

The first post in this series detailed the reasons behind the introduction of IEC 61439 while my second post covered rating current of protection devices. Complying to the standard and… Read more »

The post Clearances and Creepage Distances in LV Electrical Switchboards appeared first on Schneider Electric Blog.

Read more

Power Distribution System Characteristics: Up to 630A

Credit to Author: Petre Butu| Date: Wed, 23 May 2018 13:00:21 +0000

For panel builders, understanding how to build an electrical power distribution system is important. As noted in the introductory article, this can be done by following IEC 61439 or an… Read more »

The post Power Distribution System Characteristics: Up to 630A appeared first on Schneider Electric Blog.

Read more

Power Distribution System Characteristics: Introduction

Credit to Author: Petre Butu| Date: Wed, 09 May 2018 13:00:58 +0000

For panel builders, understanding how to distribute electrical power is important. Get that right and everything works as expected. But, if current, frequency, or operating temperature is not properly accounted… Read more »

The post Power Distribution System Characteristics: Introduction appeared first on Schneider Electric Blog.

Read more