How Electrical Conductivity and Temperature-rise Limitations Impact LV Switchboards

Credit to Author: Pascal Lepretre| Date: Mon, 27 Aug 2018 13:00:27 +0000

The first post in this series explained why following IEC 61439 ensures quality switchboards, panels and assemblies. In short, adhering to the standard means that everything in an assembly works… Read more »

The post How Electrical Conductivity and Temperature-rise Limitations Impact LV Switchboards appeared first on Schneider Electric Blog.

Read more

With IEC 61439, Assure Thermal Stability and Reliability in Low Voltage Electric Switchboards

Credit to Author: Pascal Lepretre| Date: Tue, 10 Jul 2018 12:00:52 +0000

As detailed in the first post in this series, the main reason for following IEC 61439 is that doing so ensures quality of low voltage electric switchboards, panels and assemblies…. Read more »

The post With IEC 61439, Assure Thermal Stability and Reliability in Low Voltage Electric Switchboards appeared first on Schneider Electric Blog.

Read more

Ensure Short Circuit Withstand Strength in Low Voltage Electric Switchboards

Credit to Author: Pascal Lepretre| Date: Thu, 28 Jun 2018 12:30:57 +0000

The initial post in this series covered the reasons behind IEC 61439, which when followed ensures the quality of low voltage electric switchboards. Other posts how shown how the standard… Read more »

The post Ensure Short Circuit Withstand Strength in Low Voltage Electric Switchboards appeared first on Schneider Electric Blog.

Read more

IEC 61439: Ensure Insulating Material Properties To Protect Electrical Panels

Credit to Author: Pascal Lepretre| Date: Wed, 20 Jun 2018 13:00:30 +0000

My first post in this series covered why IEC 61439 was introduced, the second detailed why it’s important to respect the rated current for devices and the third discussed reasons to satisfy clearances… Read more »

The post IEC 61439: Ensure Insulating Material Properties To Protect Electrical Panels appeared first on Schneider Electric Blog.

Read more

Clearances and Creepage Distances in LV Electrical Switchboards

Credit to Author: Pascal Lepretre| Date: Wed, 06 Jun 2018 13:00:04 +0000

The first post in this series detailed the reasons behind the introduction of IEC 61439 while my second post covered rating current of protection devices. Complying to the standard and… Read more »

The post Clearances and Creepage Distances in LV Electrical Switchboards appeared first on Schneider Electric Blog.

Read more

IEC 61439: Rated current of Electrical Panel and Switchboard Protection Devices

Credit to Author: Pascal Lepretre| Date: Wed, 23 May 2018 13:00:20 +0000

My first post went over the reasons behind the introduction of IEC 61439 and how following it can help specifiers get the outcome they want and avoid the undesirable ones…. Read more »

The post IEC 61439: Rated current of Electrical Panel and Switchboard Protection Devices appeared first on Schneider Electric Blog.

Read more

Avoid the Wrong Type of Electrical Fireworks with IEC 61439

Credit to Author: Pascal Lepretre| Date: Thu, 10 May 2018 13:00:22 +0000

Companies and organization like to be noticed when they do something right. But, nobody wants to gain attention because something went wrong. An example was a government-backed show in India… Read more »

The post Avoid the Wrong Type of Electrical Fireworks with IEC 61439 appeared first on Schneider Electric Blog.

Read more